APL: 626 12/18/2019

  • Category: 626 - Retaining Wall Systems
  • Effective Date: December 18, 2019
  • Contact: Adam M. Gillispie

This is an approved list of Mechanically Stabilized Earth (MSE) Retaining Wall Systems and does not remove the requirements for the designs and materials to be approved prior to use as per Section 626 of the Standard Specification.

See the Bridge Design Manual, Table 3.10.1.4B for applicationof these wall systems and limitations which include:

  1. 1. No utilities shall be permitted in the reinforced fill zone.
  2. 2. Reinforcement shall not be exposed to soils with low resistivity (<3,000 ohm-cm), high sulfates (200 ppm), or high chloride (100 ppm) contents.
  3. 3. Not to be used in areas with unpredictable erosion or having uncontrolled scour below the reinforced fill zone.

Mechanically Stabilized Earth (MSE) Retaining Wall Systems (Precast Concrete Panel Wall System) MSE Panels 626.002.002

Height limited to 60 ft
SystemManufacturerApproval Number
Reinforced EarthThe Reinforced Earth CompanyVienna, VA (R170A)REC1.01.6261349758A
ISOGRIDThe Neel CompanySpringfield, VA (N123A)NCX1.01.6261349759A
MSE PlusSSLScotts Valley, CA (S423A)SSL1.01.6161349760A
TriconTricon Precast, Ltd.Houston Texas (T183A)TPL1.01.6261380649A
Vista WallVist - A - Wall SystemsMansfield, TX 76063VWS1.01.6261428608A
Height Limited to 50 ft
SystemManufacturerApproval Number
Earth TracEarthTec, Inc.Purcellville, VA (E136A)EIC1.0.6261393169A
Height Limited to 40 ft
SystemManufacturerApproval Number
AresTensar Earth Technologies, InAtlanta, GA (T173A)TET1.01.6261349761A
Height Limited to 30 ft
SystemManufacturerApproval Number
*** GravixGravix Retaining Wall System1458723A
*** ElevateElevate Retaining WallsMorris, ILERW1.01.6261901279A

*** Note: Use Select Granular Backfill per Specificaiton 626.5.3.1 within the volume from the back of the wall to a vertical projected of the end of the bottom stem section to the ground surface. The remaining backfill can be random material.

MSE Wire - Faced Retainnig Wall Systems 626.002.004

Height Limited to 60 ft
SystemManufacturerApproval Number
Reinforced EarthThe Reinforced Earth CompanyVienna, VA (R170A)REC1.01.6261349763A
MSE PlusSSLScotts Valley, CA (S423A)SSL1.01.6161349764A
Height Limited to 40 ft
SystemManufacturerApproval Number
Mesa a bTensar Earth Technologies, Inc.Atlanta, GA (T173A)TET1.01.6261349766A
Ares aTensar Earth Technologies, Inc.Atlanta, GA (T173A)TET1.01.6261349761A
  1. a Can only be used as a temporary system for a maximum of three (3) years
  2. b Must be constructed with the high performance connector

Modular Block Wall Systems listed below are approved with the following conditions:

  1. 1. No utilities shall be permitted in the reinforced fill zone.
  2. 2. Not to be used in areas with erosion or scour below the reinforced fill zone.
  3. 3. Concrete must comply with requirements of Section 626.5.1.1.1.
  4. 4. Block size tolernaces must comply with the requirements of Section 626.5.1.1.2.

MSE Modular Block Wall Systems 626.002.003

Class I - Height Limited to 40 ft
SystemManufacturerApproval Number
KeySystem 1Keystone Retaining Wall Systems, Inc.Minneapolis, MN (K116A)KRW1.01.6261349765A
MesaTensar Earth Technologies, Inc.Atlanta, GA (T173A)TET1.01.6261349766A
LandmarkAnchor Wall Systems, Inc.Minnetonka, MN (A317A)AWS2.01.6261349767A
Magnum StoneSSLScotts Valley, CA (S423A)SSL1.01.6161422575A
Redi-Rock Positive Connection SystemRedi-Rock InternationalCharlvoix, MI (R183A)RRI1.01.6261425060A
Class II - Height Limited to 20 ft (Note Class I may be substituted.)
SystemManufacturerApproval Number
ReConReCon Retaining Wall Systems, Inc.St Louis Park, MN (R182A)RCR1.01.6261424718A
Verti-BlockVerti-Block Foster SupplyScott Depot, WVFSC1.01.6051458720A
Class III - Height Limited to 10 ft (Note Class I or II may be substituted.)
SystemManufacturerApproval Number
AnchorAnchor Wall Systems, Inc.Minnetonka, MN (A317A)1349770A
GenesisKeystone Retaining Wall Systems, Inc.Minneapolis, MN (K116A)KRW1.01.6261349769A
Stone StrongStone Strong SystemOmaha, NECSC1.06.6261465534A
KeystoneKeystone Retaining Wall Systems, Inc.Minneapolis, MN (K116A)KRW1.01.6261349768A
Redi-RockRedi-Rock InternationalCharlvoix, MI (R183A)RRI1.01.6261386514A
Redi-ScapesRedi-Rock InternationalCharlvoix, MI (R183A)RRI1.01.6261424719A
ReConReCon Retaining Wall systems, IncSt Louis Park, MN (R182A)RCR1.01.6261424719A
Class IV - Height Limited to 5 ft (Note Class I, II, or III may be substituted.)
SystemManufacturerApproval Number
AnchorAnchor Wall Systems, Inc.Minnetonka, MN (A317A)1349771A
KeystoneKeystone Retaining Wall Systems, Inc.Minneapolis, MN (K116A)KRW1.01.6261349772A
Redi-Rock cRedi-Rock InternationalCharlvoix, MI (R183A)RRI1.01.6261386515A

Notes and Remarks:

  1. c Allowed up to 10 ft with 41" deep blocks. Limited to 5 ft with 28" deep blocks